Unvented hot water cylinder: how it works and warning signs

Last updated 23 October 2026 · 5 minute read

Short answer: An unvented hot water cylinder stores hot water at mains pressure, so several showers can run at once without a tank in the loft. Because it is sealed, it relies on safety valves and a thermal cut out. Water dripping from the discharge pipe, a falling pressure gauge or noise from the cylinder all mean it needs checking.

Row of new copper plumbing fittings

What an unvented cylinder does

An unvented cylinder is a sealed tank of hot water fed straight from the cold mains. There is no cold water tank in the loft and no gravity feed. The water inside sits at roughly the pressure of the mains, so when you open a hot tap you get a strong flow, and two or three outlets can run together.

That is why unvented cylinders are common in bigger homes around Glasgow. In Newton Mearns, Giffnock, Clarkston, Bearsden and Milngavie, many family houses have a family bathroom, an en suite and a cloakroom. A combi boiler heats water as you use it and usually manages one shower well at a time. A system boiler and an unvented cylinder store a large amount of hot water ready to go. You can read more about that choice in our combi or system boiler guide.

The cylinder can be heated by a gas boiler through a coil inside it, by an immersion heater, or by both. Heat pump systems also use a form of unvented cylinder.

The safety devices and why they matter

A sealed vessel of hot water under pressure needs protection. Standard 4.9 of the Scottish domestic technical handbook lists what a small unvented system should have. In plain terms:

DeviceWhat it does
Pressure reducing valveKeeps the incoming mains pressure at the level the cylinder is designed for
Check valveStops hot water flowing back into the cold supply
Expansion vesselGives the water room to expand as it heats, so pressure does not climb
Expansion relief valveLets water out if the pressure goes too high
Temperature and pressure relief valveOpens if the water gets dangerously hot
Non self resetting thermal cut outSwitches off the heat source if the thermostat fails
Tundish and discharge pipeShows you when a valve has opened and carries the water to a safe, visible place

The handbook says the stored water should never exceed 100°C, and the relief valve normally opens at no more than 90°C. Those devices are on top of the normal thermostat, which keeps the water at about 60°C.

Warning signs to act on

Most unvented cylinders run quietly for years. These are the signs that something needs attention.

Water from the discharge pipe. The discharge pipe usually ends outside, often low on a wall or over a gully, through a small funnel called a tundish near the cylinder. If water is running or dripping through the tundish, a valve has opened. Cold water dripping usually means the expansion vessel has lost its air charge or the expansion relief valve is worn. Hot water or steam is more serious and points to a temperature problem. Switch off the boiler and immersion and get it checked.

Pressure changes. If the hot taps surge and then drop, or the pressure gauge on the cylinder pipework moves a lot as the water heats, the expansion vessel or the pressure reducing valve may be faulty.

Noise. Rumbling, ticking or banging as the cylinder heats can mean a valve or vessel fault. In soft water areas like Glasgow it is less likely to be scale on the immersion element than in hard water parts of England.

No hot water with the boiler running. The thermal cut out may have tripped. It does not reset itself on purpose. Find out why it tripped before resetting it.

Water at the base. A leak from a fitting can be repaired. A leak from the body of the cylinder means it needs replacing.

Soft water and unvented cylinders in Glasgow

Scottish Water’s 2024 hardness data classes the Milngavie supply zones, which carry Loch Katrine water across most of Glasgow, as soft at about 16 mg/l as calcium carbonate. The zones serving the wider area in the same table are soft or moderately soft. For an unvented cylinder that is good news. Valves and coils do not choke with scale the way they can in hard water towns, and most cylinders here do not need a softener or scale inhibitor for that reason.

The main things that wear are the rubber parts in valves, the membrane and air charge in the expansion vessel, and the immersion element. Grit from mains repairs in the street can also lodge in the strainer on the cold inlet, which is worth cleaning when the system is checked.

Mains flow comes first

An unvented cylinder can only give what the mains supply gives it. In larger plots in Newton Mearns, the supply pipe from the boundary stop cock to the house can be long, and in older homes it may be narrow or old. If the incoming flow is weak, the showers will disappoint however good the cylinder is. We measure the flow and pressure before recommending one, and sometimes renewing the supply pipe is part of the job. That pipe is the owner’s responsibility from the boundary inwards, according to Scottish Water.

Installation rules in Scotland

In Scotland you will hear about building standards and building warrants rather than English Building Regulations. The technical handbook says an unvented system should be installed by a person with appropriate training and practical experience. It mentions training administered by SNIPEF, the Scottish plumbing employers federation, and CITB, or an equivalent body. The installer should be identified on the label, the discharge should be tested, and a user manual left with you.

Ask anyone quoting for an unvented cylinder to show their unvented training. If a boiler is involved, gas work must be done by a Gas Safe registered engineer, and you can check their ID card on the Gas Safe Register.

Whether a particular job needs a building warrant depends on the property and the work, so check with your council’s building standards team. In Newton Mearns that is East Renfrewshire Council.

Looking after it

  • Leave the cupboard clear so the tundish and valves can be seen.
  • Look at the tundish now and then. It should be dry.
  • Have the safety devices checked once a year, often at the same visit as the boiler service.
  • Do not cap, block or shorten the discharge pipe.

If you are in Newton Mearns or the nearby East Renfrewshire suburbs, our Newton Mearns page covers the other systems common there. For repairs and replacements, see our hot water cylinders service.

Quick questions

Do unvented cylinders need servicing?

Scottish building standards say the safety devices should be maintained. An annual check of the expansion vessel, relief valves and discharge pipe is good practice, and many manufacturers ask for it to keep the warranty.

Who can install an unvented cylinder in Scotland?

Standard 4.9 of the domestic technical handbook says installation should be carried out by a person with appropriate training and practical experience, such as courses run through SNIPEF or CITB. Ask the installer for proof of their unvented training.

Why is water coming out of the pipe by my cylinder?

That is usually the safety discharge. It means the expansion vessel has lost its charge or a relief valve is letting by. Turn the heat source off if the water is hot and book a check.

Is an unvented cylinder worth it in a flat?

Only if the mains flow is strong enough and there is space for the cylinder and a safe discharge route. Many Glasgow flats are better suited to a combi.

The serviceHot water cylinders in Glasgow Local notesPlumber in Newton Mearns

Last updated 23 October 2026. Written for homes in Glasgow. Rules can change, so check the linked sources for the latest position.